Sized to Body Surface Area
The 1.4 m² membrane matches the circulating blood volume and BSA of paediatric patients — instead of forcing a full adult dialyzer onto a small circulatory system.
Sized specifically for children on hemodialysis. Smaller membrane surface area, lower priming volume, and a safety profile that matches paediatric circulation — not scaled-down adult equipment.
Paediatric haemodialysis uses smaller circuits, lower blood flow rates, and dialyzers sized to the child's body surface area. Using adult-sized equipment in paediatric care risks haemodynamic instability and unnecessary blood loss. Kibellan stocks dedicated paediatric dialyzers for children's dialysis units across Kenya.
Paediatric haemodialysis is a specialist discipline. The dialyzer choice affects haemodynamic stability, clearance efficiency, and total blood loss.
The 1.4 m² membrane matches the circulating blood volume and BSA of paediatric patients — instead of forcing a full adult dialyzer onto a small circulatory system.
Smaller dialyzer and lower-volume bloodline combination minimises extracorporeal blood volume — reducing the risk of hypotensive episodes during sessions.
PES membrane with high-flux capability provides effective clearance of middle-molecular toxins — critical for children on long-term dialysis as they grow.
A quick reference for procurement teams — surface area directly affects clearance and priming volume.
Matches small body surface area and circulating blood volume in paediatric patients.
| Product Name | Paediatric Dialyzers 1.4m² |
|---|---|
| SKU | PD-1400 |
| Category | Dialysis Consumables |
| Target Population | Paediatric patients |
| Surface Area | 1.4 m² |
| Membrane Material | Polyethersulfone (PES) |
| Flux Type | High Flux |
| Priming Volume | Low — appropriate for paediatric circuits |
| Sterilization | Sterile — single-use |
| Unit of Measure | Piece |
| Availability | In Stock — Nationwide delivery |
| Bulk Pricing | Available for 30+ pieces |
Children have a much lower total blood volume and body surface area than adults. Using an adult-sized dialyzer on a child can remove too much fluid, cause haemodynamic instability, and lead to significant blood loss in the extracorporeal circuit. Paediatric dialyzers have a smaller 1.4 m² membrane surface area and lower priming volume so the circuit is sized in proportion to the child's circulation.
1.4 m². This is smaller than the 1.8, 2.0 and 2.1 m² dialyzers used for adults, and is designed to match the body surface area and clearance needs of paediatric patients.
This is a high-flux paediatric dialyzer with a PES membrane. High flux provides better clearance of middle-molecular toxins like beta-2-microglobulin — important for paediatric patients on long-term dialysis. Your paediatric nephrologist selects flux type based on clinical need.
Yes. We deliver nationwide. Paediatric dialyzers are stocked and available for immediate dispatch. Nairobi and Machakos deliveries arrive in 1 working day; other counties within 2–3 working days.
Yes. Every institutional order includes batch number, lot number, manufacturing date, expiry date, and the manufacturer's Certificate of Analysis where applicable. This documentation supports paediatric procurement audits and regulatory reviews.
Tell us quantity and delivery location. We confirm availability within 24 hours.